Weathertight roof cladding for warehouses, factories and commercial buildings — standing seam, box profile and insulated panel systems supplied and installed by our own site teams, working to full fall-protection standards.
What is Roof Cladding?
Roof cladding is the external covering fixed over a building’s roof structure to keep it weathertight, insulated and durable. On industrial and commercial buildings this typically means profiled steel or aluminium sheet, either fixed directly to purlins or built up with an insulated core as part of a composite roof panel system.
A correctly specified roof system also has to manage rainwater run-off, thermal movement and — critically — safe access for installation and future maintenance, which is why roof projects are planned around fall-protection measures from the outset.
Roof Cladding Systems We Install
At Faclade, we supply and install a range of roof cladding systems to suit different roof pitches, spans and performance requirements. Our team manages the process — from system specification and material procurement through to professional installation and final sign-off.
Box Profile & Trapezoidal Roof Sheeting
Corrugated or trapezoidal steel sheet fixed directly to purlins. The standard, cost-effective roofing solution for warehouses, agricultural and industrial buildings, with Class A1 non-combustible ratings as standard.
Standing Seam Roof Systems
Concealed-fix standing seam roofing in aluminium, zinc or steel, allowing very low pitches and giving a smooth, weathertight finish. A common choice where appearance and long-term watertightness are the priority.
Insulated Composite Roof Panels
Twin-skin panels with a continuous insulating core, combining weatherproofing and thermal performance in a single fixing operation. Widely specified for cold stores, logistics buildings and buildings needing to meet current Part L requirements.
Roof Cladding and UK Building Regulations
Roof cladding sits within the same fire safety and structural framework as wall cladding, alongside specific requirements for roof access, fall protection and rainwater management. The correct system depends on the roof’s pitch, span, use and the building’s overall fire strategy.
Key regulatory points that commonly apply to roof cladding projects:
- Non-combustible roof coverings rated Class A1 or A2-s1,d0 are typically required on relevant buildings above certain height thresholds — the exact requirement depends on the building’s use and classification, so each project is assessed individually
- Insulated roof panel systems are commonly specified with reference to BS EN 14509, with the core material determining the overall fire classification
- Roof works are subject to the Work at Height Regulations 2005, requiring fall-protection measures such as edge protection, safety netting or harness systems throughout installation
- The Building Safety Act 2022 introduced new duties for building owners, developers and contractors on higher-risk buildings
At Faclade, every roof cladding installation is specified and installed with reference to current UK building regulations and health and safety legislation. We work alongside the project’s fire and design professionals, and provide the relevant system documentation for the specification used.
Roof Cladding Installation Process
Our installation process follows a structured programme designed to deliver consistent quality, comply with CWCT standards, and keep our teams and the site safe throughout.
1. Site Survey & Specification
Our technical team visits the site to assess roof pitch, span, structural condition and access requirements. We produce a detailed specification document outlining the recommended profile, insulation and fixing method, plus a full access and fall-protection plan.
2. Material Procurement
We source roof sheet and panel systems from approved UK and European manufacturers, ensuring full traceability and certification on every coil and panel.
3. Access & Safety Setup
Before any sheeting begins, we install edge protection, safety netting and any required harness anchor points in line with the Work at Height Regulations 2005.
4. Purlin Preparation & Sheeting
Sheets or panels are fixed to purlins with correct overlaps, side laps and fixing centres for the site’s wind-load and exposure data, with insulation installed where the system requires it.
5. Quality Inspection & Sign-off
Every Faclade roof installation undergoes a comprehensive quality inspection before handover, including water testing where required. We provide full as-built documentation and system warranties.
Roof Cladding Cost Guide — UK 2026
Roof cladding costs vary depending on material, profile, insulation and roof access requirements. The figures below are indicative supply-and-install guide prices for typical UK commercial and industrial projects in 2026 — see the notes under the table for what’s included.
Why Choose Faclade for Roof Cladding?
- Full project management from specification to sign-off — one point of contact
- Specified and installed with reference to the Building Safety Act 2022 and Approved Document B
- Fall-protection and access planning built into every roof project from day one
- Materials sourced from approved manufacturers with full traceability documentation
- Experienced roofing teams with CSCS cards, working at height certification and relevant trade qualifications
- Comprehensive warranties covering both materials and workmanship
- Coverage across the UK and internationally
Roof cladding types we install
Box Profile Sheeting
Trapezoidal steel sheet fixed directly to purlins. The standard, cost-effective roofing solution for industrial buildings.
Standing Seam Roofing
Concealed-fix seam system allowing very low pitches, with a smooth architectural finish for commercial roofs.
Insulated Composite Roof Panels
Twin-skin panels with a continuous insulating core, installed in one operation for warehouses and cold stores.
Secret-Fix Roof Systems
Concealed fixings with no exposed fasteners, reducing the risk of water ingress at fixing points over the roof’s lifespan.
Rooflight Integration
Polycarbonate or GRP rooflights integrated into the sheeting run to bring natural daylight into the building below.
Roof Liner & Membrane Systems
Internal liner panels and vapour control layers that work alongside the outer roof sheet to manage condensation and thermal performance.
Roof cladding cost guide UK 2026
| System Type | Fire Rating | Supply Cost (per m²) | Installed Cost (per m²) | Best For |
|---|---|---|---|---|
| Box Profile Sheeting | Class A1 | £14 – £25 | £35 – £55 | Single-storey industrial |
| Insulated Composite Panel | A2-s1,d0 / B | £32 – £55 | £75 – £125 | Warehouses, cold stores |
| Standing Seam Roofing | A1 | £45 – £80 | £100 – £150 | Architectural / low pitch |
| Secret-Fix System | A1 | £35 – £58 | £80 – £120 | Long-life, low-maintenance |
| Re-roof / Overcladding | A2-s1,d0 / B | £30 – £55 | £70 – £115 | Ageing roof upgrades |
* Prices are indicative supply-and-install guide prices for UK commercial and industrial projects in 2026, covering material and standard labour. They exclude VAT, scaffolding/access equipment, structural repairs and non-standard substructure work unless otherwise agreed. Final costs depend on roof pitch, access requirements, insulation specification and project complexity. Contact Faclade for a detailed project quotation.
Specified to current UK regulations
Every roof cladding project delivered by Faclade is specified and installed with reference to current UK building regulations and health and safety legislation. We provide the relevant system documentation for the specification used on every installation.
Roof cladding questions answered
Ready to discuss your roof cladding project?
Our team will review your enquiry within one working day. A detailed specification and cost plan follows once we have your project drawings and information.